<div>The Hi Delta® line of fan-assisted combustion units offer solid performance and flexible controls with easy-to-understand diagnostics.</div>
<div> </div>
<div><strong>Features:</strong></div>
<ul>
<li>83.1% efficiency</li>
<li>Elevation: 0-5000 Feet</li>
<li>Multiple vertical venting and sidewall venting options. No extractor required for sidewall applications up to 70ft on room air.</li>
<li>All models indoor/outdoor certified</li>
<li>Patented burner "security blanket" enhances staged combustion, minimizes installation/start-up issues, and protects burners from metal fatigue.</li>
<li>105ºF minimum inlet water temperature</li>
<li>Cupro-nickel finned-tube heat exchanger with brass headers. AB 1953 compliant.</li>
<li>VERSA IC® control package with LCD display</li>
<li>Status display lights</li>
<li>Cascade control of up to 4 units, no external sequencer required</li>
<li>Diagnostics center with history in English , not in codes</li>
<li>Modbus RTU BMS port (RS485)</li>
<li>0-10 VDC BMS Interface (set point or direct drive)</li>
<li>Ducted combustion air capable. TruSeal® CSA-Certified direct-vent available.</li>
<li>Models 992C-2002C certified to SCAQMD Rule 1146.2. Meets all Low NOx regulations.</li>
<li>All models except 2002C available for natural gas and propane. Model 2002C available for natural gas only.</li>
<li>Certified to the ANSI Z21.56 pool heater standard.</li>
</ul>
<div><strong>VERSA IC Boiler Control and On-Board Diagnostic Center</strong></div>
<div>VERSA IC merges safety, ignition, temperature control, multi-unit cascade outdoor reset, and freeze protection. Plus system monitoring, diagnostics, and BMS transmission all in one Integrated Control Platform. Easy front access to read, set up and trouble shoot on a 3.5" LCD screen. The entire package is CSA certified, and listed for each individual function.</div>
<div> </div>
<div>Inlet and outlet sensors factory installed in boiler. Remote sensor for system included. BMS all point diagnostics transmission port. 0-10VDC set point input standard. Can drive and monitor external motorized auxiliaries such as extractors and louvers. Additional connections for auxiliaryfunctions, indirect DHW, and dry contact remote alarm relay are provided.</div>
<div> </div>
<div><strong>Bypass Options:</strong></div>
<ul>
<li>The standard external bypass uses an external bypass to achieve cold-water protection</li>
<li>All units available without an external bypass; cold-water protection provided in the field</li>
<li>The Cold Water Run (CWR) option provides electronic control of a variable-speed pump to continuously adjust bypass flow, achieving real-time cold-water protection </li>
</ul>
<div><strong>Cold Water Start</strong></div>
<div>It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without harmful condensation at lower inlet water temperatures than the competition, there are still applications that require reliable protection against harmful condensation caused by frequent, extended, cold water startups. Raypak's Cold Water Start protection system is only used with closed-loop heating systems and utilizes a proportional three-way valve to bypass water from the boiler outlet to the inlet during start-up, when the system return water temperature is below the minimum acceptable level.</div>
<div> </div>
<div><strong>Cold Water Run</strong></div>
<div>For the same reason stated for Cold Water Starts, it is even more important to provide protection against condensation from cold inlet water on systems where the return water temperature to the boiler will always be below the acceptable minimum. Raypak's Cold Water Run system can be used on boilers, water heaters or pool heaters, and utilizes a variable-speed pump to inject just the right amount of water from the main system loop into the boiler to maintain the optimum inlet temperature. This approach allows the full capacity of the boiler to be utilized to meet the system load, while at the same time continuously maintaining the optimum inlet water temperature to prevent condensation. (See Cat. #1000.19)</div>