Sta-Rite 14965-0006 top mount Cristal-Flo multiport valve springSta-Rite Top Mount Cristal-Flo Valve Spring In stock$2799
Sta-Rite 14965-0006 top mount Cristal-Flo multiport valve spring

Sta-Rite Top Mount Cristal-Flo Valve Spring

Ask a questionMPN 14965-0006
$2799
In stock

30 day returns · Easy, with prepaid labels provided

Quick overview

  • Sta-Rite 14965-0006 The factory spring for the top mount multiport valve, not a hardware store substitute.
  • Fits the WC112-148 Used in the 1-1/2 inch Cristal-Flo and Waterford top mount valve.
  • Holds the diverter down The spring is what keeps the valve key seated against the seat plate.
  • Cheap fix for a leaking valve A tired spring lets water bypass between ports, which reads as a filter that never quite backwashes clean.
  • Small part, whole job Worth replacing whenever the valve is open for a cover o-ring or key rebuild.
  • Genuine Sta-Rite The OEM part rather than an aftermarket wind.
Full description and specifications ↓

Need a hand?

Bilingual support from pool professionals.

Send us a message

A pool professional will get back to you, usually the same business day.

About Sta-Rite Top Mount Cristal-Flo Valve Spring, SKU STA-061-5816. We will include it with your message.

We use your details to answer this message and nothing else.

Frequently bought together

Current item Sta-Rite Top Mount Cristal-Flo Valve Spring
Sta-Rite

Top Mount Cristal-Flo Valve Spring

$2799
Sta-Rite 170145 System 3 S7M120 Large and Small Cartridge Set, 25021-0200S and 25022-0201S
Pentair

Sta-Rite 170145 System 3 S7M120 Large and Small Cartridge Set, 25021-0200S and 25022-0201S

$47999
Filbur Sta-Rite S7D75 Full Filter Grid Set (11 Grids)
Unicel Filter Cartridges

Filbur Sta-Rite S7D75 Full Filter Grid Set (11 Grids)

$25399
Pentair Genuine OEM Valve Body O-Ring for Cristal-Flo II and Sand Dollar Filters
Pentair

Genuine OEM Valve Body O-Ring for Cristal-Flo II and Sand Dollar Filters

$1199
Pentair Genuine OEM Triton II Air Relief Tee Assembly
Pentair

Genuine OEM Triton II Air Relief Tee Assembly

$3599
Pentair Genuine OEM Sand Filter Drain Cap
Pentair

Genuine OEM Sand Filter Drain Cap

$3525
Sta-Rite 21 in. Filter Tank O-Ring, System 3
Sta-Rite

21 in. Filter Tank O-Ring, System 3

$7299
Subtotal

Product details

This is the Sta-Rite 14965-0006 valve spring for the 1-1/2 inch top mount multiport valve fitted to Cristal-Flo and Waterford filters, model WC112-148.

What the spring does

Inside a top mount multiport, the diverter key has to press firmly against the seat plate so each port is sealed off from the others. The spring supplies that pressure. When it weakens or breaks, the key floats and water crosses between ports, which usually shows up as dirty water returning to the pool after a backwash, or as a slow loss to waste while filtering.

Fitting it

The spring sits under the valve cover with the key assembly, so the valve has to come apart to reach it. Since you are already there, it is worth inspecting the cover o-ring and the seat gasket and replacing them in the same visit.

Specifications
Brand Sta-Rite
Manufacturer part number 14965-0006
UPC 788379784546
Part type Filter Valves Part
Fits Sta-Rite 1-1/2 inch top mount Cristal-Flo and Waterford WC112-148 valve
Shipping weight 0.35 lb
Ships Parcel

Request a quote

Need a volume price, a freight quote, or pricing in writing before you order? We reply the same business day.

Request a quote

Customer reviews

Questions and answers

What people ask about this product, answered by our pool techs.

Which valve does this spring belong to?
The Sta-Rite 1-1/2 inch top mount multiport valve used on Cristal-Flo and Waterford filters, model WC112-148.
What goes wrong when the spring is weak?
The valve key stops sitting firmly on the seat plate, so water sneaks between ports. Backwash water reaches the return, or filtered water trickles to waste.
Is it a genuine Sta-Rite part?
Yes. This is the OEM part, number 14965-0006.
Should I replace anything else at the same time?
If the valve is apart, most techs also renew the cover o-ring and check the diverter gasket, since the labor is already spent.